Mica Nozzle Heaters
Features Construction Applications Techical Data Tech-Specification Std. Size
 
     Mica Nozzle Heaters - Technical Specification
 
 Clampings
 
 
Barrel Nut
Std. M6 x 45mm
 
Flange Lock - ½” Height
 Terminal Connection
 
Chrome Nickel Steel
Terminal Box at 180°
opposite to clamping
 
Electric Terminal Connections for Mica Nozzle Heaters above 40mm dia will be provided with Chrome Nickel Steel protection caps at center of width either at 180° opposite the Clamping or 90° from Clamping, unless specified.

Note : All Mica Nozzle Heaters Below 60mm Dia will not have Screw Post Terminals

 
Chrome Nickel Steel braid existing both sides of gap.
 
Nozzle Heaters below 40mm Dia will NOT have Protection Caps for Terminals, but have Direct cable terminal exit through edges on both sides of gap.

Note : All Mica Nozzle Heaters Below 60mm Dia will not have Screw Post Terminals

 Terminal Location
 
Single Piece
 Thermocouple Holes
 
 
All Thermocouple Holes for Mica Nozzle Heaters (if required) will be provided at center of width either at 180° opposite the Clamping or 90° from Clamping, unless specified along with drawing.
Note: As far as possible please avoid thermocouple holes. Try and locate them in the heater gap, since holes in the heater body complicates the internal wiring resulting in less heating area and also turns out to be more expensive.
Oversize Gap: The nominal gap between the clamping is 10mm. If a larger gap is required for probes or thermocouples, specify when ordering.
 Thermocouple location (if required)
 
 
 
Limitation for holes in Nozzle Heaters is :
Min Width : 50 mm, Min Dia : 40 mm
T/c holes at center of width for Single Piece
 
 
    Mica Nozzle Heaters - Variations
 
Single Phase
Vinman's band heaters are usually designed on 230 Volts single phase unless specified.
Dual Phase
Mica Nozzle Heaters can be designed with multiple circuits to operate in single or dual-phase circuits.
 
 
Top     